Present temperature field characterization and geothermal resource assessment in the Harbin Area, Northeast China

9Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Seven steady-state temperature profiles are logged in the Harbin Area, Northeast China. The temperature data illustrate high conductive thermal gradients with a mean value of 4.78°C/100 m. Temperature maps at depths of 1000, 1500, and 1800 m are represented. The present temperature field is cooling southeastward, with the highest thermal gradients being observed at the junction zone between the Central Depression and the Southeast Uplift of the Songliao Basin. The recoverable heat is calculated using a volumetric method and Monte Carlo simulation. The mean value for recoverable heat from the detailed exploration area around the Harbin Area is 1.052 × 1019 J (3.59 × 1011 t standard coal). Geological controls on the present temperature fields are discussed.

Cite

CITATION STYLE

APA

Shi, Y., Jiang, G., Zhang, X., Yuan, Z., Wang, Z., Qiu, Q., & Hu, S. (2019). Present temperature field characterization and geothermal resource assessment in the Harbin Area, Northeast China. Energy Exploration and Exploitation, 37(2), 834–848. https://doi.org/10.1177/0144598718815922

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley