Abstract
Indoor area is an area that lacks a signal so that the signal attenuation continues to be problems that often occur. To overcome these problems need the support of a communication system that can include a signal in the room so that customers can keep communicate with smoothly. The need for application of indoor mobile communications system to support the outdoor system that can serve the entire mobile service users. This research discusses the planning of indoor femtocell LTE 4G network at the electronics building of the Balikpapan State Polytechnic is on the floor 1,2 and 3 with models Cost 231 multiwall indoor propagation. This design is simulated using 5.4 Software Radiowave Propagation Simulator (RPS). From the calculation results, the number of Femtocell Access Points (FAP) on each floor is 3, the placement of FAP in the middle part of each floor of the Electronics building. From the design results obtained on the 1st floor RSRP value of -32.18 dBm and SIR of 12.31 dB, for floors 2 RSRP -34.20 dBm and SIR of 13.52 dB, and floor 3 RSRP value of -33.32 dBm and SIR is 13.27 dBArea Indoor merupakan area yang kurang mendapatkan sinyal sehingga pelemahan sinyal terus menjadi permasalahan yang sering terjadi. Untuk mengatasi permasalahan tersebut perlu adanya dukungan sistem komunikasi yang dapat mencakup sinyal didalam ruangan agar pelanggan dapat tetap berkomunikasi dengan lancar. Perlunya penerapan sistem komunikasi seluler indoor dilakukan untuk mendukung sistem outdoor sehingga layanan seluler dapat melayani seluruh user.Penelitian ini membahas perancangan jaringan indoor femtocell 4G LTE pada gedung Elektronika Politeknik Negeri Balikpapan pada lantai 1,2 dan 3 dengan model propagasi Cost 231 multiwall indoor. Perancangan ini disimulasikan dengan menggunakan Software Radiowave Propagation Simulator 5.4 (RPS). Dari hasil perhitungan didapatkan jumlah Femtocell Access Point (FAP) pada setiap lantainya sebanyak 3 buah, penempatan FAP di bagian tengah disetiap lantai gedung Elektronika. Dari hasil perancangan didapatkan pada lantai 1 nilai RSRP -32,18 dBm dan SIR sebesar 12,31 dB, untuk lantai 2 RSRP -34,20 dBm dan SIR sebesar 13,52 dB, dan lantai 3 nilai RSRP -33,32 dBm dan SIR sebesar 13,27 dB
Cite
CITATION STYLE
Ulfah, M., & Tadung, N. P. (2019). PERANCANGAN JARINGAN INDOOR 4G LTE 1800 MHZ GEDUNG ELELKTRONIKA POLITEKNIK NEGERI BALIKPAPAN MENGGUNAKAN RADIOWAVE PROPAGATION SIMULATOR 5.4. Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering), 6(1), 40–48. https://doi.org/10.33019/ecotipe.v6i1.950
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.