Abstract
The heat leakage of cryogenic transfer lines directly influences the performance of large-scale helium refrigerator. In this paper, a thermal model of cryogenic transfer line considering numerical simulation of support coupled with MLI was established. To validate the model, test platform of cryogenic transfer lines with the merits of disassembly outer pipe and changeable easily multi-layer insulation has been built. The experimental results of heat leakage through overall length of cryogenic transfer lines, support and multi-layer insulation were obtained. The heat leakages of multi-layer insulation, a support and the overall leakage are 1.02 W/m, 0.44 W and 1.46 W/m from experimental data, respectively. The difference of heat leakage of MLI between experiment and simulation were less than 5%. The temperature distribution of support and MLI obtained in presented model in good agreement with experimental data. It is expected to reduce the overall heat leakage of cryogenic transfer lines further by optimizing structure of support based on the above thermal model and test platform in this paper.
Cite
CITATION STYLE
Deng, B. C., Xie, X. J., Pan, W., Jiang, R. X., Li, J., Yang, S. Q., & Li, Q. (2017). Simulation and experimental research of heat leakage of cryogenic transfer lines. In IOP Conference Series: Materials Science and Engineering (Vol. 278). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/278/1/012017