Role of pulmonary function in the detection of allograft dysfunction after heart-lung transplantation

66Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

Background - Lung function is altered by infection and rejection in patients who undergo heart-lung transplantation. The sensitivity, specificity, and positive/negative predictive values (PPV and NPV) of lung function for the detection of allograft dysfunction in these patients were measured. Methods - Thirty three patients who underwent heart-lung transplantation were followed for a mean period of 16.3 months. On 123 occasions functional measurements were obtained at the time a transbronchial biopsy specimen and/or bronchoalveolar lavage fluid was taken, which were used as gold standards. Optimal sensitivity (the value for which sensitivity equals specificity) was computed for each functional test from receiver- operator characteristic (ROC) curves. Results - Acute rejection was present on 31 occasions and infection on 36 occasions; 56 samples were normal. Infection and rejection were accompanied by airflow obstruction, a rise in the slopes of the alveolar plateaus for nitrogen, hexafluoride sulphur and helium (SN2, SSF6, and SHe), and a decrease in the difference between SSF6 and SHe (ΔS), total lung capacity (TLC), and lung transfer factor (TLCO). Optimal sensitivities for SHe, mid forced expiratory flow (FEF25-75), TLC, and forced expiratory volume in one second (FEV1) were 68%, 67%, 66%, and 60%, respectively; they were not different for infection and rejection and did not change over the study period. For infection and rejection together, PPV ranged from 72% to 88% and NPV from 27% to 52% according to the functional test and the postoperative period considered. Conclusions - Indices of ventilation distribution, FEF25-75, and TLC have the best optimal sensitivity for the diagnosis of infection and rejection after heart- lung transplantation. The high PPV of pulmonary function in detecting allograft dysfunction observed in this study suggests that a diagnostic procedure should be performed whenever one or more functional tests deteriorate; conversely, the low NPV indicates that a stable pulmonary function does not rule out allograft dysfunction.

Cite

CITATION STYLE

APA

Van Muylem, A., Mélot, C., Antoine, M., Knoop, C., & Estenne, M. (1997). Role of pulmonary function in the detection of allograft dysfunction after heart-lung transplantation. Thorax, 52(7), 643–647. https://doi.org/10.1136/thx.52.7.643

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free