Girder deformation related phase errors on the undulators for the European X-Ray Free Electron Laser

9Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

In long gap tunable undulators, strong magnetic forces always lead to some amount of gap-dependent girder deformation and resulting gap-dependent phase errors. For the undulators for the European XFEL, this problem has been investigated thoroughly and quantitatively. Using the different gap dependencies of suitable shims and pole height tuning, a method is presented which can be applied to reduce the overall gap dependence of the phase error if needed. It is exemplified by tuning one of the undulator segments for the European X-Ray Free Electron Laser back to specs.

Cite

CITATION STYLE

APA

Li, Y., Ketenoglu, B., & Pflueger, J. (2015). Girder deformation related phase errors on the undulators for the European X-Ray Free Electron Laser. Physical Review Special Topics - Accelerators and Beams, 18(6). https://doi.org/10.1103/PhysRevSTAB.18.060704

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free