In vivo model of human pathogen infection and demonstration of efficacy by an antimicrobial pouch for pacing devices

57Citations
Citations of this article
44Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Device-related infections represent a significant clinical challenge. Once established, these infections prove difficult to treat with existing antibiotic regimens, compromising the health of device recipients, and usually requiring surgical intervention to resolve. Objective: The purpose of this study was to determine the efficacy of the AIGIS RX™ antibacterial envelope (TyRx Pharma, Inc., Monmouth Junction, NJ, USA) designed to reduce device-related infections by incorporating minocycline and rifampin in a controlled release polymer. Methods: An infection was established in a rabbit model by creating bilateral subcutaneous implant pockets, into which a pacing device with or without AIGIS RX™ was placed. The incisions were closed, and a defined dose of bacteria was infused into each implant pocket. After 7 days, devices were explanted and sampled for viable bacteria by swabbing and sonication. Results: Initial studies evaluated the ability of the AIGIS RX pouch to reduce Staphylococcus epidermidis (S. epi) infection in this model using clinical and quantitative microbial endpoints. Results demonstrate S. epi infection in all control samples, while no pathogens were recovered from samples with the AIGIS RX™ pouch. Systemic antibiotic levels were undetectable. Additional studies tested the efficacy of the AIGIS RX™ pouch with additional bacterial strains, Staphylococcus capitis, Escherichia coli, and Acinetobacter Baumannii. In each case, the device and implant pocket with the AIGIS RX™ pouch was free of any signs of infection. An assessment of biofilm produced by Acinetobacter demonstrated the elimination of biofilm formation on the implanted device. Conclusion: These results demonstrate that in this animal model, the AIGIS RX™ device reduces the risk for infection of viable pathogens within implant pockets. (PACE 2009; 32:898-907) © 2009 Wiley Periodicals, Inc.

Author supplied keywords

Cite

CITATION STYLE

APA

Hansen, L. K., Brown, M., Johnson, D., Palme, D. F., Love, C., & Darouiche, R. (2009). In vivo model of human pathogen infection and demonstration of efficacy by an antimicrobial pouch for pacing devices. PACE - Pacing and Clinical Electrophysiology, 32(7), 898–907. https://doi.org/10.1111/j.1540-8159.2009.02406.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free