To investigate factors that influence graft failure after Descemet membrane endothelial keratoplasty (DMEK) based on transmission electron microscopy results. Retrospective observational case series. This single center study included 16 eyes of 16 patients with penetrating keratoplasty (n = 14) or repeat DMEK (n = 2) following graft failure after DMEK. The main outcome measures were ultrastructural changes in the explanted graft on transmission electron microscopy, best-corrected visual acuity, and central corneal thickness. The mean preoperative and postoperative best-corrected visual acuity was 1.01 ± 0.54 logMAR and 0.56 ± 0.37 logMAR. The mean central corneal preoperative and postoperative thickness was 667 ± 187 mm and 511 ± 42 mm. Visual acuity and central corneal thickness improved significantly (P = .001/P = .003) after repeat surgery. Electron microscopy showed that 3 of 14 corneas showed upside down transplantation, and 3 corneas had pigmented cells or pigment granules at the Descemet–stroma interface. Further, 9 of 16 specimens showed a posterior collagenous layer deposited onto the Descemet membrane (average thickness 5.1 ± 6.2 mm; ranged 0.65–20 mm); this did not correlate significantly with the time between the original and repeat keratoplasty. Of 16 original grafts, 7 showed ultrastructural anomalies of the Descemet membrane, but one excised cornea showed no Descemet membrane pathologies. The majority of eyes with graft failure after DMEK showed ultrastructural changes in the Descemet membrane. It is crucial to assess donor tissue quality and to conduct graft marking before surgery to avoid immediate or delayed graft failure after DMEK. Nevertheless, repeat keratoplasty provided significant improvement in central corneal thickness and visual acuity. Abbreviations: ABL = anterior banded layer, BCVA = best-corrected visual acuity, CCT = central corneal thickness, DMEK = Descemet membrane endothelial keratoplasty, MAR = minimum angle of resolution, PCL = posterior collagenous layer, PEX = pseudoexfoliation syndrome, PNBL = posterior nonbanded layer, YAG = yttrium aluminum garnet.
CITATION STYLE
Schmidt, I., Schlötzer-Schrehardt, U., Langenbucher, A., Eppig, T., Hager, T., Zimpfer, A., & Seitz, B. (2019). Ultrastructural findings in graft failure after Descemet membrane endothelial keratoplasty (DMEK) and new triple procedure. Medicine (United States), 98(19). https://doi.org/10.1097/MD.0000000000015493
Mendeley helps you to discover research relevant for your work.