Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile

39Citations
Citations of this article
59Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Lung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist. Methods. In 40 patients, we measured the respiratory variables during intraoperative mechanical ventilation. All measurements were subdivided into 5 min intervals. Dynamic compliance (CRS) and the intratidal volume-dependent CRS curve was calculated for each interval and classified into one of the six specific compliance profiles indicating intratidal recruitment/derecruitment, overdistension or all. We retrospectively compared the occurrences of the respective compliance profiles at PEEP levels of 5 cm H2O and at higher levels. Results. The attending anaesthetists set the PEEP level initially to 5 cm H2O in 29 patients (83%), to 7 cm H2O in 5 patients (14%), and to 8 cm H2O in 2 patients (6%). Across all measurements the mean CRS was 61 (11) ml cm H2O-1 (40-86 ml cm H2O-1) and decreased continuously during the procedure. At PEEP of 5 cm H2O the compliance profile indicating strong intratidal recruitment/derecruitment occurred more often (18.6%) compared with higher PEEP levels (5.5%, P<0.01). Overdistension was practically never observed. Conclusions. In most patients, a PEEP of 5 cm H2O during intraoperative mechanical ventilation is too low to prevent intratidal recruitment/derecruitment. The analysis of the intratidal compliance profile provides the rationale to individually titrate a PEEP level that stabilizes the alveolar recruitment status of the lung during intraoperative mechanical ventilation.

Cite

CITATION STYLE

APA

Wirth, S., Baur, M., Spaeth, J., Guttmann, J., & Schumann, S. (2015). Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile. British Journal of Anaesthesia, 114(3), 483–490. https://doi.org/10.1093/bja/aeu385

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free