Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek automicrobic system for identification of gram-negative bacilli

45Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A comparative evaluation of the Crystal Enteric/Nonfermenter system (Crystal; Becton Dickinson, Cockeysville, Md.), API 20E (API; bioMerieux Vitek, Inc., Hazelwood, Mo.), and the Vitek GNI card (Vitek; bioMerieux Vitek) was performed with 512 clinical isolates of gram-negative bacilli, including 381 members of the family Enterobacteriaceae and 131 nonenteric bacilli. With supplemental testing, API, Crystal, and Vitek correctly identified to the genus and species level 505 (98.6%), 489 (95.5%), and 494 (96.5%) of the 512 isolates, respectively. Supplemental testing, as specified by the manufacturer, was required to identify 119 (23.2%), 18 (3.5%), and 5 (1.0%) of the isolates with the three systems, respectively. Of the 381 isolates from the family Enterobacteriaceae, API and Crystal correctly identified 90.3 and 91.6% by 18 to 24 h without supplemental testing, respectively, and Vitek identified 92.4 and 96.1% following 10 and 18 h of incubation, respectively. Of the 131 nonenteric organisms, API and Crystal correctly identified 28.2 and 93.9% by 18 to 24 h without supplemental testing, respectively, and Vitek identified 84.0% by 10 h and 93.9% by 18 h. Errors in identification with each system were infrequent and appeared to be randomly distributed among the genera evaluated. The three systems were comparable in accuracy when either a weighted clinical laboratory profile of organisms or a group of selected isolates in a stress test sample was evaluated (P > 0.05). There were no significant differences between the three systems in their ability to identify either the isolates in the weighted group or those in the stress test (P > 0.05). Significantly more isolates required supplemental testing with API than with Crystal or Vitek (P < 0.05). Crystal compared favorably with API and Vitek, which have established track records in clinical laboratories, and is acceptable for the identification of members of the Enterobacteriaceae and nonenteric bacilli in a clinical microbiology laboratory.

Cite

CITATION STYLE

APA

Robinson, A., McCarter, Y. S., & Tetreault, J. (1995). Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek automicrobic system for identification of gram-negative bacilli. Journal of Clinical Microbiology, 33(2), 364–370. https://doi.org/10.1128/jcm.33.2.364-370.1995

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free