Low-level laser therapy with a 635 nm diode laser affects orthodontic mini-implants stability: A randomized clinical split-mouth trial

41Citations
Citations of this article
83Readers
Mendeley users who have this article in their library.

Abstract

Background: The study aimed to clinically estimate an influence of a 635 nm diode laser on the stability of orthodontic mini-implants, to assess mini-implants loss, and to evaluate a pain level after the treatment. Materials and Methods: The randomized clinical split-mouth trial included 20 subjects (13 women and 7 men; age: 32.5 ± 6.1 years), 40 implants (RMO, West Colfax Ave., Denver, CO, USA) with a diameter 1.4 mm and length of 10 mm. Mini-implants were placed in the area of the attached gingiva between the second premolar and first molar teeth, 2 mm below the mucogingival junction of both sides of the maxilla. Each implant on the right side (G1, n = 20) of the maxilla was irradiated with a diode laser, and the implants on the opposite side (left, G2, n = 20) were a control group (without laser irradiation). The 635-nm laser parameters; dose: 10 J per point (20 J/cm2), time: 100 s per point, two points (irradiation on a buccal, and a palatal side of the alveolus/implant), the total energy per session 20 J. Laser application protocol: immediately and 3, 6, 9, 12, 15, and 30 days after surgery. The total energy after all therapeutic sessions was 140 J. The implants’ stability was measured employing a Periotest device (Periotest Test Value—PTV) immediately and 3, 6, 9, 12, 15, 30, and 60 days after the insertion of the mini-implants. Results: We found significantly higher secondary stability, lower mean PTV (6.18 ± 5.30) and (1.51 ± 2.25), for self-drilling mini-implants (G1, test group) in contrast to the control, G2 group (9.17 ± 8.25) and (5.00 ± 3.24), after 30 (p = 0.0003) and 60 days (p = 0.0000). Moreover, the analysis of the mini-implants stability after 635-nm diode laser application revealed significant higher stability in comparison with none irradiated implants (G2 group) after 3 days. (p = 0.0000) There was no significant difference in pain level measured on the NRS-11 scale on both sides of the maxilla. (p = 0.3665) An important finding was that all inserted mini-implants survived during a two-month observation period. Conclusions: 635-nm diode laser at laser irradiation increases the secondary stability of orthodontic mini-implants.

Cite

CITATION STYLE

APA

Flieger, R., Gedrange, T., Grzech-Leśniak, K., Dominiak, M., & Matys, J. (2020). Low-level laser therapy with a 635 nm diode laser affects orthodontic mini-implants stability: A randomized clinical split-mouth trial. Journal of Clinical Medicine, 9(1). https://doi.org/10.3390/jcm9010112

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free