Abstract
A 22-year-old male admitted with multiple gunshot wounds (GSW) had central line placed initially for hemodynamic monitoring and later for long term antibiotics and total parenteral nutrition (TPN). On postoperative day 4 he presented with bouts of nonsustained ventricular tachycardia; the cause was unknown initially and later attributed to a catheter fragment accidentally severed and lodged in the right heart. Percutaneous retrieval technique was used to successfully extract the catheter fragment and complete recovery was achieved.
Cite
CITATION STYLE
Biswas, S., & McNerney, P. (2015). Ventricular Tachycardia from a Central Line Fracture Fragment Embolus: A Rare Complication of a Commonly Used Procedure—A Case Report and Review of the Relevant Literature. Case Reports in Critical Care, 2015, 1–6. https://doi.org/10.1155/2015/265326
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.