Abstract
Purpose:For aortic coarctation in adults endovascular repair is the treatment of choice with an acceptable safety profile. Aortic isthmus atresia is a related condition with a complete occlusion of the aorta not allowing catheterization across the isthmus. This technical note describes a recanalization of an aortic isthmus atresia using radiofrequency with an “electrified wire technique.”Technique:A guidewire was selectively denuded of PTFE (polytetrafluoroethylene) at the distal end and was placed through a catheter distal to the aortic isthmus atresia. The denuded end of the wire was clamped to an electrosurgery pencil. By pushing the wire toward a tulip-snare, which was placed as a target proximal of the occlusion via left trans-brachial access, and shortly activating of the electrosurgery pencil the electrified wire recanalized the occlusion and was snared and used to guide implantation of a balloon-expandable covered stent.Conclusion:The electrified wire puncture technique can be used to recanalize adult aortic isthmus atresia after failed conventional attempts.Clinical ImpactThe electrified wire technique offers an off-the shelf option to modify standard guidewires for the use with radiofrequency to cross a complete aortic isthmus occlusion after failed conventional attempts. This new technique may be applied also in other situations like dissection flap fenestration, transcaval access and similar.
Author supplied keywords
Cite
CITATION STYLE
Arulrajah, K., Spanos, K., Panuccio, G., Gandet, T., Rickers, C., & Kölbel, T. (2025). Endovascular Recanalization of Aortic Isthmus Atresia with an “Electrified Wire Technique.” Journal of Endovascular Therapy, 32(4), 994–998. https://doi.org/10.1177/15266028231206996
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.