PREDICTION METHOD OF FLOW PATTERN IN SUBCOOLED AND LOW QUALITY BOILING REGIONS.

14Citations
Citations of this article
4Readers
Mendeley users who have this article in their library.

Abstract

A new parameter is proposed for prediction of the transition between flow patterns such as bubble, froth and annular flow, in both the subcooled and low quality regions of boiling flow. This parameter is derived from the theoretical calculation method of void fraction, which has been reported, on the assumption that the flow pattern transition occurs at a value of average void fraction over the cross section of the flow. A flow map is also presented which reasonably correlates the experimental results covering the following conditions; pressure: 1 approximately 98 ata, heat flux: 2 multiplied by 10**4 approximately 5 multiplied by 10**6kcal/m**2h, and mass velocity: 40 approximately 5400kg/m**2s.

Cite

CITATION STYLE

APA

Sekoguchi, K., Tanaka, O., Esaki, S., Katsuki, N., & Nakasatomi, M. (1981). PREDICTION METHOD OF FLOW PATTERN IN SUBCOOLED AND LOW QUALITY BOILING REGIONS. Bulletin of the JSME, 24(191), 834–841. https://doi.org/10.1299/jsme1958.24.834