Thrombin generation assay using factor XIa to measure factors VIII and IX and their glycoPEGylated derivatives is robust and sensitive

28Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Conventional coagulation factor assays are associated with certain limitations, as they do not always reflect the clinical heterogeneity of bleeding in hemophilic patients or correctly reflect the individual patient response to treatment with bypassing agents or novel factor concentrates. The thrombin generation assay (TGA) is currently being assessed as a possible method for characterizing bleeding phenotypes in individuals with hemophilia. Objectives: This study assessed the robustness and sensitivity of the TGA for measuring the activity of recombinant factor VIII (rFVIII), recombinant factor IX (rFIX) and their glycoPEGylated derivatives, N8-GP and N9-GP, in vitro. Methods: Factor-deficient plasma was spiked with 0.13-130 IU dL-1 rFVIII or N8-GP (hemophilia A [HA] plasma), or rFIX or N9-GP (hemophilia B [HB] plasma). A calibrated automated thrombogram triggered with tissue factor (TF) or activated FXI (FXIa) was used to measure thrombin generation over time. Endogenous thrombin potential, peak thrombin, velocity index, lag time and time to peak thrombin were analyzed. Results: FXIa-triggered assays were not affected by glycoPEGylation and were sufficiently sensitive to differentiate between spiked samples mimicking severe and moderate HB and HA; TF-triggered assays were not sufficiently sensitive for this distinction in HA. Both FXIa-triggered and TF-triggered assays had an acceptable level of variability (≤ 20%), although TF-triggered assays were associated with greater variability. Conclusions: FXIa-triggered TGA reactions produced more robust and sensitive results than TF-triggered TGA reactions, and have the potential for use in monitoring patients treated with glycoPEGylated or non-PEGylated coagulation factor concentrates. These promising results merit confirmation with clinical samples to correlate in vitro and in vivo data.

Cite

CITATION STYLE

APA

Waters, E. K., Hilden, I., Sørensen, B. B., Ezban, M., & Holm, P. K. (2015). Thrombin generation assay using factor XIa to measure factors VIII and IX and their glycoPEGylated derivatives is robust and sensitive. Journal of Thrombosis and Haemostasis, 13(11), 2041–2052. https://doi.org/10.1111/jth.13134

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free