Rapid reconstruction of four-dimensional mr angiography of the thoracic aorta using a convolutional neural network

13Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To implement an integrated reconstruction pipeline including a graphics processing unit (GPU)–based convolutional neural network (CNN) architecture and test whether it reconstructs four-dimensional non-Cartesian, non–contrast material–enhanced MR angiographic k-space data faster than a central processing unit (CPU)–based compressed sensing (CS) reconstruction pipeline, without significant losses in data fidelity, summed visual score (SVS), or arterial vessel–diameter measurements. Materials and Methods: Raw k-space data of 24 patients (18 men and six women; mean age, 56.8 years 6 11.8 [standard deviation]) suspected of having thoracic aortic disease were used to evaluate the proposed reconstruction pipeline derived from an open-source threedimensional CNN. For training, 4800 zero-filled images and the corresponding CS-reconstructed images from 10 patients were used as input-output pairs. For testing, 6720 zero-filled images from 14 different patients were used as inputs to a trained CNN. Metrics for evaluating the agreement between the CNN and CS images included reconstruction times, structural similarity index (SSIM) and normalized root-mean-square error (NRMSE), SVS (3 = nondiagnostic, 9 = clinically acceptable, 15 = excellent), and vessel diameters. Results: The mean reconstruction time was 65 times and 69 times shorter for the CPU-based and GPU-based CNN pipelines (216.6 seconds 6 40.5 and 204.9 seconds 6 40.5), respectively, than for CS (14 152.3 seconds 6 1708.6) (P, .001). Compared with CS as practical ground truth, CNNs produced high data fidelity (SSIM = 0.94 6 0.02, NRMSE = 2.8% 6 0.4) and not significantly different (P = .25) SVS and aortic diameters, except at one out of seven locations, where the percentage difference was only 3% (ie, clinically irrelevant). Conclusion: The proposed integrated reconstruction pipeline including a CNN architecture is capable of rapidly reconstructing timeresolved volumetric cardiovascular MRI k-space data, without a significant loss in data quality, thereby supporting clinical translation of said non–contrast-enhanced MR angiograms.

Cite

CITATION STYLE

APA

Haji-Valizadeh, H., Shen, D., Avery, R. J., Serhal, A. M., Schiffers, F. A., Katsaggelos, A. K., … Kim, D. (2020). Rapid reconstruction of four-dimensional mr angiography of the thoracic aorta using a convolutional neural network. Radiology: Cardiothoracic Imaging, 2(3). https://doi.org/10.1148/ryct.2020190205

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free