Understanding the Effects of PEMFC Contamination from Balance of Plant Assembly Aids Materials: In Situ Studies

  • Opu M
  • Bender G
  • Macomber C
  • et al.
16Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In situ performance data were measured to assess the degree of contamination from leachates of five families of balance of plant (BOP) materials (i.e., 2-part adhesive, grease, thread lock/seal, silicone adhesive/seal and urethane adhesive/seal) broadly classified as assembly AIDS that may be used as adhesives and lubricants in polymer electrolyte membrane fuel cell (PEMFC) systems. Leachate solutions, derived from soaking the materials in deionized (DI) water at elevated temperature, were infused into the fuel cell to determine the effect of the leachates on fuel cell performance. During the contamination phase of the experiments, leachate solution was introduced through a nebulizer into the cathode feed stream of a 50 cm 2 PEMFC operating at 0.2 A/cm 2 at 80°C and 32%RH. Voltage loss and high frequency resistance (HFR) were measured as a function of time and electrochemical surface area (ECA) before and after contamination were compared. Two procedures of recovery, one self-induced recovery with DI water and one driven recovery through cyclic voltammetry (CV) were investigated. Performance results measured before and after contamination and after CV recovery are compared and discussed.

Cite

CITATION STYLE

APA

Opu, Md., Bender, G., Macomber, C. S., Van Zee, J. W., & Dinh, H. N. (2015). Understanding the Effects of PEMFC Contamination from Balance of Plant Assembly Aids Materials: In Situ Studies. Journal of The Electrochemical Society, 162(9), F1011–F1019. https://doi.org/10.1149/2.0411509jes

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free