Effect of dimension of specimen on amounts of Cesium-137, Strontium-90 and Cobalt-60 leached from matrix of hardened cement grout

10Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The relationship between the fraction leached and the ratio of surface area and volume (S/V) of a specimen has been studied in order to evaluate the safety of a cement composite for disposal. The leaching fraction of radionuclides was measured for the different S/V ratios. In a case of either137Cs,90Sr or60Co, the amount leached is directly proportional to the S/V ratio. It is in harmony with the empirical formula proposed here, which can be derived from the diffusion equation with a semi-infinite plane source model. The amounts of137Cs,90Sr and60Co leached from a cement composite of 200 l drum size are estimated on the basis of the above relation, referring to the data obtained with a cylindrical shape specimen (4.5cm in dia. and 4.4cm high). © 1978 Taylor & Francis Group, LLC.

Cite

CITATION STYLE

APA

Matsuzuru, H., & Ito, A. (1978). Effect of dimension of specimen on amounts of Cesium-137, Strontium-90 and Cobalt-60 leached from matrix of hardened cement grout. Journal of Nuclear Science and Technology, 15(4), 296–301. https://doi.org/10.1080/18811248.1978.9733214