Total target volume is a better predictor of whole brain dose from gamma stereotactic radiosurgery than the number, shape, or location of the lesions

12Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To assess the hypothesis that the volume of whole brain that receives a certain dose level is primarily dependent on the treated volume rather than on the number, shape, or location of the lesions. This would help a physician validate the suitability of GammaKnife® based stereotactic radiosurgery (GKSR) prior to treatment. Methods: Simulation studies were performed to establish the hypothesis for both oblong and spherical shaped lesions of various numbers and sizes. Forty patients who underwent GKSR [mean age of 54 years (range 7-80), mean number of lesions of 2.5 (range 1-6), and mean lesion volume of 4.4 cm3 (range 0.02-22.2 cm3)] were also studied retrospectively. Following recommendations of QUANTEC, the volume of brain irradiated by the 12 Gy (VB12) isodose line was measured and a power-law based relation is proposed here for estimating VB12 from the known tumor volume and the prescription dose. Results: In the simulation study on oblong, spherical, and multiple lesions, the volume of brain irradiated by 50%, 10%, and 1% of maximum dose was found to have linear, linear, and exponentially increasing dependence on the volume of the treated region, respectively. In the retrospective study on 40 GKSR patients, a similar relationship was found to predict the brain dose with a Spearman correlation coefficient >0.9. In both the studies, the volume of brain irradiated by a certain dose level does not have a statistically significant relationship (p ≥ 0.05) with the number, shape, or position of the lesions. The measured VB12 agrees with calculation to within 1.7%. Conclusions: The results from the simulation and the retrospective clinical studies indicate that the volume of whole brain that receives a certain percentage of the maximum dose is primarily dependent on the treated volume and less on the number, shape, and location of the lesions. © 2013 American Association of Physicists in Medicine.

Cite

CITATION STYLE

APA

Narayanasamy, G., Smith, A., Van Meter, E., McGarry, R., & Molloy, J. A. (2013). Total target volume is a better predictor of whole brain dose from gamma stereotactic radiosurgery than the number, shape, or location of the lesions. Medical Physics, 40(9). https://doi.org/10.1118/1.4818825

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free