Emissão de gases do efeito estufa de um aterro sanitário no Rio de Janeiro

  • Borba P
  • Martins E
  • Correa S
  • et al.
N/ACitations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

RESUMO A emissão de metano (CH4) e dióxido de carbono (CO2) em aterros sanitários representa uma das mais importantes fontes de gases de efeito estufa em regiões metropolitanas. O presente trabalho quantificou a taxa de emissão de gases do efeito estufa (GEEs) pela camada de cobertura intermediária do aterro sanitário de Seropédica, Rio de Janeiro, Brasil, assim como a concentração desses gases na atmosfera acima das células do aterro. Um total de 21 amostras na camada de cobertura e 31 na atmosfera acima do aterro foi coletado. Foram utilizadas duas câmaras de fluxo de 0,66 m2 de área e 33,2 L de volume, e amostras foram retiradas com seringas de polipropileno de 60 mL em intervalos de 5 minutos, durante 15 minutos. As amostras foram coletadas em locais com e sem fissura na camada de cobertura intermediária. A análise das amostras foi feita por cromatografia de fase gasosa, por múltiplos detectores. As taxas de emissão dos GEEs observadas variaram entre 0,1 e 575,0 g m-2 dia-1 para CH4 e entre 0,1 e 316,0 g m-2 dia-1 para CO2. As concentrações no ar ambiente variaram entre 3,5 e 150,0 ppm e entre 333 e 655 ppm, para CH4 e CO2, respectivamente. As maiores emissões foram constatadas nos pontos que continham as maiores fissuras no momento da coleta.ABSTRACT The emission of methane (CH4) and carbon dioxide (CO2) from landfills is one of the most important sources of greenhouse gases in metropolitan areas. This study quantified the emission rate of greenhouse gases (GHGs) by the intermediate cover layer of Seropédica landfill, in Rio de Janeiro, Brazil, as well as the concentration of these gases in the atmosphere above the landfill cells. A total of 21 samples from the cover layer and 31 samples from the atmosphere above the landfill was collected. Two flow chambers with 0.66 m2 and 33.2 L were used, and the samples were collected with 60 mL polypropylene syringes at five-minute intervals, for 15 minutes. The samples were collected in areas with and without cracks in the intermediate cover layer. Sample analysis was performed by gas chromatography, by multiple detectors. GHGs emission rates varied from 0.1 to 575.0 g m-2 day-1 for CH4 and 0.1 to 316.0 g m-2 day-1 for CO2. The ambient air concentrations ranged from 3.5 to 150.0 ppm and 333 to 655 ppm for CH4 and CO2, respectively. Higher emissions were found in areas containing the larger cracks at the time of collection.

Cite

CITATION STYLE

APA

Borba, P. F. de S., Martins, E. M., Correa, S. M., & Ritter, E. (2018). Emissão de gases do efeito estufa de um aterro sanitário no Rio de Janeiro. Engenharia Sanitaria e Ambiental, 23(1), 101–111. https://doi.org/10.1590/s1413-41522018167438

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free