Abstract
In this study, the low-cycle fatigue (LCF) behaviour of API 5L X65 pipeline steel was investigated under fully-reversed straincontrolled conditions at room temperature. The companion test method was used to obtain the cyclic stress-strain response curve with strain amplitudes ranging between 0.3% and 1.2%. Results showed that the steel undergoes both cyclic hardening and softening behaviour depending on the strain amplitude. At relatively lower strain amplitudes (0.3 - 0.8%), only cyclic softening was observed whereas at higher strain amplitudes, softening behaviour was preceded by significant hardening in the first few cycles. Based on the cyclic half-life results, the LCF life decreased while stress amplitude and plastic strain amplitude increased with total strain amplitude. Furthermore, analysis of stabilised hysteresis loops showed that the steel exhibits non-Masing behaviour. Complimentary scanning electron microscopy examinations were also carried out on fracture surfaces to reveal dominant damage mechanisms during crack initiation, propagation and fracture. © 2014 The Authors. Published by Elsevier Ltd.
Author supplied keywords
Cite
CITATION STYLE
Fatoba, O., & Akid, R. (2014). Low cycle fatigue behaviour of API 5L X65 pipeline steel at room temperature. In Procedia Engineering (Vol. 74, pp. 279–286). Elsevier Ltd. https://doi.org/10.1016/j.proeng.2014.06.263
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.