Performance comparison of a flow cytometry immunoassay for intracellular cytokine staining and the QuantiFERON® SARS-CoV-2 test for detection and quantification of SARS-CoV-2-Spike-reactive-IFN-γ-producing T cells after COVID-19 vaccination

15Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: We compared the performance of an in-house-developed flow cytometry assay for intracellular cytokine staining (FC-ICS) and a commercially-available cytokine release assay (the QuantiFERON® SARS-CoV-2 Test [QF]) for detection and quantification of SARS-CoV-2-Spike (S)-reactive-IFN-γ-producing T cells after COVID-19 vaccination. Patients and methods: The sample included 141 individuals (all male; median age, 42 years; 20–72) who had been fully vaccinated with the Comirnaty® COVID-19 vaccine (at a median of 114 days; 34–145). Prior to vaccination, 91 were categorized as being SARS-CoV-2-naïve and 50 as SARS-CoV-2-experienced. A whole blood-based FC-ICS using 15-mer overlapping peptides encompassing the entire SARS-CoV-2 S protein was used for enumeration of virus-specific IFN-γ-producing CD4+ and CD8+ T cells. The QF test (Ag1 for CD4+ T cells and Ag2 for CD4+ and CD8+ T cells in combination) was carried out following the manufacturer’s instructions. Results: The FC-ICS and the QF assays returned significantly discordant qualitative results in both the entire cohort (P<0.001 with QF Ag1 and QF Ag2) and in SARS-CoV-2-naïve participants alone (P=0.005 and P=0.01, respectively). Discrepant results mostly involved FC-ICS positive/QF negative specimens. Overall, no correlation was found either between SARS-CoV-2 IFN-γ- CD4+ T-cell frequencies and IFN-γ levels measured in the QF Ag1 tube (P=0.78) or between the sum of SARS-CoV-2 IFN-γ CD4+ and CD8+ T-cell frequencies and IFN-γ levels quantified in the QF Ag2 tube. Conclusion: The data suggest a greater sensitivity for the FC-ICS assay than the QF test, and urge caution when comparing SARS-CoV-2 T-cell immune responses assessed using different analytical platforms.

Cite

CITATION STYLE

APA

Tormo, N., Giménez, E., Martínez-Navarro, M., Albert, E., Navalpotro, D., Torres, I., … Navarro, D. (2022). Performance comparison of a flow cytometry immunoassay for intracellular cytokine staining and the QuantiFERON® SARS-CoV-2 test for detection and quantification of SARS-CoV-2-Spike-reactive-IFN-γ-producing T cells after COVID-19 vaccination. European Journal of Clinical Microbiology and Infectious Diseases, 41(4), 657–662. https://doi.org/10.1007/s10096-022-04422-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free