Investigation of the radiation hardness of GaAs sensors in an electron beam

39Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

A compact and finely grained sandwich calorimeter is designed to instrument the very forward region of a detector at a future e+e- collider. The calorimeter will be exposed to low energy e+e - pairs originating from beamstrahlung, resulting in absorbed doses of about one MGy per year. GaAs pad sensors interleaved with tungsten absorber plates are considered as an option for this calorimeter. Several Cr-doped GaAs sensor prototypes were produced and irradiated with 8.5-10 MeV electrons up to a dose of 1.5 MGy. The sensor performance was measured as a function of the absorbed dose. © 2012 IOP Publishing Ltd and Sissa Medialab srl.

Cite

CITATION STYLE

APA

Afanaciev, K., Bergholz, M., Bernitt, P., Chelkov, G., Gajewski, J., Gostkin, M., … Tyazhev, A. (2012). Investigation of the radiation hardness of GaAs sensors in an electron beam. Journal of Instrumentation, 7(11). https://doi.org/10.1088/1748-0221/7/11/P11022

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free