A new automated NaCl based robust method for routine production of gallium-68 labeled peptides

58Citations
Citations of this article
76Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A new NaCl based method for preparation of gallium-68 labeled radiopharmaceuticals has been adapted for use with an automated gallium-68 generator system. The method was evaluated based on 56 preparations of [68Ga]DOTATOC and compared to a similar acetone-based approach. Advantages of the new NaCl approach include reduced preparation time (<15min) and removal of organic solvents. The method produces high peptide-bound % (>97%), and specific activity (>40MBqnmole-1 [68Ga]DOTATOC) and is well-suited for clinical production of radiopharmaceuticals. © 2012 Elsevier Ltd.

Cite

CITATION STYLE

APA

Schultz, M. K., Mueller, D., Baum, R. P., Leonard Watkins, G., & Breeman, W. A. P. (2013). A new automated NaCl based robust method for routine production of gallium-68 labeled peptides. Applied Radiation and Isotopes, 76, 46–54. https://doi.org/10.1016/j.apradiso.2012.08.011

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free