Abstract
This paper examines the performance of a three-phase interior permanent-magnet generator used in a portable ac generator when directly driving isolated single-phase (1-ph) ac loads. The performance of the generator was compared under three alternative connections: 1) 1-ph star; 2) 1-ph delta; and 3) a proposed 'open delta' connection. The voltage regulation, total harmonic distortion, and efficiency as three main performance criteria of the portable generators were examined using analytical calculation, finite element simulation, and experimental measurements.
Author supplied keywords
Cite
CITATION STYLE
Kahourzade, S., Soong, W. L., & Lillington, P. (2017). Single-Phase Loading Behavior of the Isolated 3ph Spoke Interior Permanent-Magnet Generator. IEEE Transactions on Industry Applications, 53(3), 1860–1869. https://doi.org/10.1109/TIA.2016.2645508
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.