Technical feasibility of constant-load and high-intensity interval training for cardiopulmonary conditioning using a re-engineered dynamic leg press

  • Chrif F
  • Nef T
  • Hunt K
N/ACitations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND: Leg-press devices are one of the most widely used training tools for musculoskeletal strengthening of the lower-limbs, and have demonstrated important cardiopulmonary benefits for healthy and patient populations. Further engineering development was done on a dynamic leg-press for work-rate estimation by integrating force and motion sensors, power calculation and a visual feedback system for volitional work-rate control. This study aimed to assess the feasibility of the enhanced dynamic leg press for cardiopulmonary exercise training in constant-load training and high-intensity interval training. Five healthy participants aged 31.0±3.9 years (mean ± standard deviation) performed two cardiopulmonary training sessions: constant-load training and high-intensity interval training. Participants carried out the training sessions at a work rate that corresponds to their first ventilatory threshold for constant-load training, and their second ventilatory threshold for high-intensity interval training. RESULTS: All participants tolerated both training protocols, and could complete the training sessions with no complications. Substantial cardiopulmonary responses were observed. The difference between mean oxygen uptake and target oxygen uptake was 0.07±0.34 L/min (103 ±17%) during constant-load training, and 0.35±0.66 L/min (113 ±27%) during high-intensity interval training. The difference between mean heart rate and target heart rate was -7±19 bpm (94 ±15%) during constant-load training, and 4.2±16 bpm (103 ±12%) during high-intensity interval training. CONCLUSIONS: The enhanced dynamic leg press was found to be feasible for cardiopulmonary exercise training, and for exercise prescription for different training programmes based on the ventilatory thresholds.

Cite

CITATION STYLE

APA

Chrif, F., Nef, T., & Hunt, K. J. (2019). Technical feasibility of constant-load and high-intensity interval training for cardiopulmonary conditioning using a re-engineered dynamic leg press. BMC Biomedical Engineering, 1(1). https://doi.org/10.1186/s42490-019-0025-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free