New bipolar tissue ligator combines constant tissue compression and temperature guidance: Histologic study and implications for treatment of hemorrhoids

6Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Background: Several minimally invasive technologies are available to treat common soft tissue lesions including symptomatic hemorrhoids. The use of energy to deliver heat and coagulate target lesions is commonly practiced. This study compares the histologic effects produced on intestinal tissues by two energy-based systems which employ different approaches of heat delivery. Methods: Two heat delivery systems were evaluated in vivo in a single porcine subject: infrared coagulator and bipolar tissue ligator utilizing constant tissue compression and temperature guidance. Eighteen treatment sites divided into three groups of six were assessed. Treatment site temperature was measured and the effects of thermal treatment in the mucosa, submucosa, submucosal vessels, and muscularis layer were scored. Lateral thermal spread beyond the energy application site was also assessed. Results: Treatment site temperatures were much lower in the bipolar ligator group than in the infrared coagulator group. The mucosal and submucosal tissue changes observed in tissues treated with infrared energy and bipolar energy at 55°C were similar. Both the mucosal and submucosal tissue changes with bipolar energy at 50°C were significantly less. Conclusion: Both devices achieved similar histologic results. However, the unique design of the bipolar ligator, which allows consistent capture, constant compression, and temperature monitoring of target tissue, accomplished the desired histologic changes with less muscular damage at much lower temperatures than the infrared coagulator. The use of bipolar ligation could offer clinical advantages such as reduced patient pain and a minimized chance of heat-related collateral tissue damage. © 2012 Piskun and Tucker, publisher and licensee Dove Medical Press Ltd.

Cite

CITATION STYLE

APA

Piskun, G., & Tucker, R. (2012). New bipolar tissue ligator combines constant tissue compression and temperature guidance: Histologic study and implications for treatment of hemorrhoids. Medical Devices: Evidence and Research, 5(1), 89–96. https://doi.org/10.2147/MDER.S34390

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free