How many patients fulfil the surface electrocardiogram criteria for subcutaneous implantable cardioverter-defibrillator implantation?

93Citations
Citations of this article
64Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims To determine the number of patients with a primary or secondary prevention implantable cardioverter-defibrillator (ICD) indication who are eligible for subcutaneous ICD (S-ICD) implantation according to the S-ICD manufacturer's surface electrocardiogram (ECG) screening template. Methods and results One hundred and ninety-six ICD patients with a non-paced ventricle were assessed using erect and supine ECG limb lead recordings to simulate the three S-ICD sensing vectors. Each ECG lead was scrutinized by two independent observers. Subcutaneous ICD eligibility required two or more leads to satisfy the S-ICD screening template in both erect and supine positions. Overall, 85.2% of patients [95% confidence interval (CI): 80.2-90.2%] fulfilled surface ECG screening criteria. The proportion of patients with 3, 2, 1, and 0 qualifying leads were 37.2% (95% CI: 30.4-44.0%), 48.0% (95% CI: 41.0-55.0%), 11.2% (95% CI: 6.8-15.6%), and 3.6% (95% CI: 1.0-6.2%). The S-ICD screening template was satisfied more often by Lead III (primary vector, 83.7%, 95% CI: 78.5-88.9%) and Lead II (secondary vector, 82.7%, 95% CI: 77.4-88.0%) compared with Lead I (alternate vector, 52.6%, 95% CI: 45.6-59.6%). A prolonged QRS duration was the only baseline characteristic independently associated with ineligibility for S-ICD implantation. There was 92.9% agreement between the two independent observers in assessment of eligibility using the S-ICD screening template. Conclusion About 85.2% of patients with an indication for a primary or secondary prevention ICD have a surface ECG that is suitable for S-ICD implantation when assessed with an S-ICD screening template. There is minor inter-observer variation in assessment of eligibility using the S-ICD screening template. © The Author 2013.

Cite

CITATION STYLE

APA

Randles, D. A., Hawkins, N. M., Shaw, M., Patwala, A. Y., Pettit, S. J., & Wright, D. J. (2014). How many patients fulfil the surface electrocardiogram criteria for subcutaneous implantable cardioverter-defibrillator implantation? Europace, 16(7), 1015–1021. https://doi.org/10.1093/europace/eut370

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free