Validating EEG source imaging using intracranial electrical stimulation

10Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Electrical source imaging is used in presurgical epilepsy evaluation and in cognitive neurosciences to localize neuronal sources of brain potentials recorded on EEG. This study evaluates the spatial accuracy of electrical source imaging for known sources, using electrical stimulation potentials recorded on simultaneous stereo-EEG and 37-electrode scalp EEG, and identifies factors determining the localization error. In 11 patients undergoing simultaneous stereo-EEG and 37-electrode scalp EEG recordings, sequential series of 99-110 biphasic pulses (2 ms pulse width) were applied by bipolar electrical stimulation on adjacent contacts of implanted stereo-EEG electrodes. The scalp EEG correlates of stimulation potentials were recorded with a sampling rate of 30 kHz. Electrical source imaging of averaged stimulation potentials was calculated utilizing a dipole source model of peak stimulation potentials based on individual four-compartment finite element method head models with various skull conductivities (range from 0.0413 to 0.001 S/m). Fitted dipoles with a goodness of fit of ≥80% were included in the analysis. The localization error was calculated using the Euclidean distance between the estimated dipoles and the centre point of adjacent stimulating contacts. A total of 3619 stimulation locations, respectively, dipole localizations, were included in the evaluation. Mean localization errors ranged from 10.3 to 26 mm, depending on source depth and selected skull conductivity. The mean localization error increased with an increase in source depth (r(3617) = [0.19], P = 0.000) and decreased with an increase in skull conductivity (r(3617) = [-0.26], P = 0.000). High skull conductivities (0.0413-0.0118 S/m) yielded significantly lower localization errors for all source depths. For superficial sources (<20 mm from the inner skull), all skull conductivities yielded insignificantly different localization errors. However, for deeper sources, in particular >40 mm, high skull conductivities of 0.0413 and 0.0206 S/m yielded significantly lower localization errors. In relation to stimulation locations, the majority of estimated dipoles moved outward-forward-downward to inward-forward-downward with a decrease in source depth and an increase in skull conductivity. Multivariate analysis revealed that an increase in source depth, number of skull holes and white matter volume, while a decrease in skull conductivity independently led to higher localization error. This evaluation of electrical source imaging accuracy using artificial patterns with a high signal-to-noise ratio supports its application in presurgical epilepsy evaluation and cognitive neurosciences. In our artificial potential model, optimizing the selected skull conductivity minimized the localization error. Future studies should examine if this accounts for true neural signals.

Cite

CITATION STYLE

APA

Unnwongse, K., Rampp, S., Wehner, T., Kowoll, A., Parpaley, Y., Von Lehe, M., … Wellmer, J. (2023). Validating EEG source imaging using intracranial electrical stimulation. Brain Communications, 5(1). https://doi.org/10.1093/braincomms/fcad023

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free