Micropulse laser trabeculoplasty on Chinese patients with glaucoma or ocular hypertension: average 35 months follow-up results

2Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Glaucoma is a group of eye diseases that can damage the optic nerve and cause vision loss. A novel technology micropulse laser trabeculoplasty (MLT) can use duty-circle subvisible laser pulses to treat glaucoma. The aim of this study is to evaluate the efficacy of 360° MLT to alleviate intraocular pressure (IOP) in patients with glaucoma. Methods: This was a single-center prospective study on patients treated with 360° MLT using a Diode True-Yellow 577-nm Laser with MicroPulse technology. All the patients were recruited from the Department of Ophthalmology. Follow-up visits were carried out at 1 day, 1 week, 1 month, 3 months, 6 months, 18 months, and 36 months after the procedure. Best-corrected visual acuity (BCVA), Intraocular pressure (IOP), and vertical cup-to-disc ratio (C/D ratio) were measured during the follow-up. Repeated-measures analysis of variance (ANOVA) and Kaplan–Meier analysis were performed to evaluate the outcomes. Results: A total of 39 eyes from 25 patients were included in this study (10 men/15 women). The average age of patients was 41.47 ± 14.39 years old, and the baseline IOP was 21.13 ± 7.75 mmHg. MLT significantly reduced the IOP at 1 day (range 15.61–19.01, P = 0.0218), 3 months (range 16.47–19.22, P = 0.0390), and 6 months (range 15.38–18.56, P = 0.0332) compared with the baseline. However, by the end of the study, only 21.88% of patients demonstrated a ≥ 20% IOP reduction, while seven eyes needed further laser or surgical treatment. The IOP of glaucoma patients was significantly lower than the ocular hypertension patients at 1 month (P = 0.0124), 3 months (P = 0.0004), 18 months (P = 0.0061) and 36 months (P = 0.0119). Conclusions: Micropulse laser trabeculoplasty reduce IOP in patients with glaucoma or ocular hypertension for a short period, but its lowering efficiency is limited up to 6 months of the follow-up period.

Cite

CITATION STYLE

APA

Yang, Y., Huang, X., Liao, S., Zhang, F., Shi, J., Duan, X., & Liu, K. (2022). Micropulse laser trabeculoplasty on Chinese patients with glaucoma or ocular hypertension: average 35 months follow-up results. BMC Ophthalmology, 22(1). https://doi.org/10.1186/s12886-022-02477-w

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free