Abstract
This paper discusses a new test vessel developed to investigate the breakdown test performance of gas insulation. The test vessel is equipped with certain specialty including pressure chamber and control measures. Through help from a steering, it is provide of controlling the gap length of the electrodes without the need of removing the gas. Other control measures include humidity, temperature, and pressure readings. The humidity and temperature are read wirelessly and from the readings, the necessary atmospheric corrections can be made according to standards. The developed vessel is then tested with AC breakdown test using air with various gap lengths and various electrode configurations. There are two types of electrode configuration used in this project i.e., rod (R0.5)-plane and plane-plane.
Author supplied keywords
Cite
CITATION STYLE
Zahari, A., Zainuddin, H., Kamarudin, M. S., Ambo, N. F., Wari, J. M., & Chairul, I. S. (2018). Development of test vessel for gas insulation breakdown test. International Journal of Power Electronics and Drive Systems, 9(2), 873–879. https://doi.org/10.11591/ijpeds.v9.i2.pp873-879
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.