Design of a vertical annulus with mhd flow using entropy generation analysis

22Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Optimal design of a heat exchanger is one of the concerns of energy conversion engineers. In the present work, the mixed convection flow between two vertical concentric pipes with constant heat flux at the boundaries andMHDflow effects is considered. To determine the optimal design for such a heat exchanger, at first, the momentum and energy equations are simplified and solved analytically. Next, using entropy generation analysis and cost analysis, the operational costs due to entropy generation are estimated. It is concluded that with an increase in the Hartmann number, the energy costs increase. In addition, for two small deviations from the base radius ratio (P = 2) including P = 19 and P = 2.1, the changes in the energy cost are calculated. It is found that for P = 1.9 the energy cost increases by 17.5% while for P = 2.1 the energy cost is reduced by 13.6%.

Cite

CITATION STYLE

APA

Mahian, O., Oztop, H. F., Pop, I., Mahmud, S., & Wongwises, S. (2013). Design of a vertical annulus with mhd flow using entropy generation analysis. Thermal Science, 17(4), 1013–1022. https://doi.org/10.2298/TSCI121017038M