Background: Despite the many advantages of real-time fluorescence reverse transcription-PCR (RT-PCR) as a quantitative analytical tool, simultaneous quantification of target and reference templates within one reaction has not been reported. We developed such an assay with an internal reference template. Methods: For quantification of target and reference sequences, we used two fluorescent probes in one reaction vessel on an AB1 PRISM 7700 SDS instrument. Fluorescent probes were labeled with either 6-carboxy-fluorescein or hexachloro-6-carboxy-fluorescein as reporter dye and 4-(4′-dimethylaminophenylazo)benzoic acid (DABCYL) as a dark quencher fluorophore. To test the sensitivity and specificity of this assay, serial dilutions of reference and target templates were analyzed in one PCR reaction. In the presence of 10 β-actin molecules as control templates, 105 bcr/abl molecules were amplified, and 105 β-actin molecules were amplified in the presence of 10 bcr/abl copies. We also performed single and duplex measurements on samples from five patients with documented Philadelphia chromosome-positive chronic myelogenous leukemia disease courses (72 samples) and three with minor bcr/abl+ acute myelogenous leukemias (26 samples). Results: For M-bcr/abl duplex RT-PCR, the correlation coefficient (r) for starting template amounts and threshold cycle values was 0.99; for m-bcr/abl, r = 0.96, indicating a precise log-linear relation for 10-105 copies/100 ng of cDNA. In the same PCR reactions, r = 0.99 for β-actin (coamplified with M-bcr/abl or m-bcr/abl) for 103-107 copies/100 ng cDNA. The linear correlation coefficient for single and duplex measurements was 0.98 for M- and m-bcr/abl in patient samples. Conclusions: DABCYL can be used as dark quencher fluorophore in real-time fluorescence PCR. The duplex fluorescence RT-PCR assay for bcr/abl and β-actin transcripts allows monitoring of bcr/abl+ leukemias. © 2001 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Kreuzer, K. A., Bohn, A., Lupberger, J., Solassol, J., Le Coutre, P., & Schmidt, C. A. (2001). Simultaneous absolute quantification of target and control templates by real-time fluorescence reverse transcription-PCR using 4-(4′-dimethylaminophenylazo)bezoic acid as a dark quencher dye. Clinical Chemistry, 47(3), 486–490. https://doi.org/10.1093/clinchem/47.3.486

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free