Performance over time and durability assessment of external thermal insulation systems with artificial stone cladding

1Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The contribution describes an experimental programme on durability assessment using the accelerated ageing of an outer wall component consisting of plasterboard support, an external thermal insulation composite system (ETICS) in polystyrene and a cladding that was realised half with natural stone and the other half with cast stone. The sample was placed in front of the climatic chamber by means of a special frame, in the so-called door configuration. During the accelerated ageing, this sample was simultaneously monitored over time using temperatures probes and flowmeter tests in order to evaluate the decay of the thermal performance over time. The experimental research was conducted with the aim of assessing the decay in thermal performance of an ETICS covered with artificial stone, comparing it with a similar stratigraphy but with a natural stone cladding.

Cite

CITATION STYLE

APA

Lupica Spagnolo, S., & Daniotti, B. (2020). Performance over time and durability assessment of external thermal insulation systems with artificial stone cladding. In Research for Development (pp. 277–287). Springer. https://doi.org/10.1007/978-3-030-33256-3_26

Register to see more suggestions