Dark Matter Search Results from the PICO-60 C3 F8 Bubble Chamber

287Citations
Citations of this article
58Readers
Mendeley users who have this article in their library.

Abstract

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C3F8 exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10-41 cm2 for a 30-GeV c-2 WIMP, more than 1 order of magnitude improvement from previous PICO results.

Cite

CITATION STYLE

APA

Amole, C., Ardid, M., Arnquist, I. J., Asner, D. M., Baxter, D., Behnke, E., … Zhang, J. (2017). Dark Matter Search Results from the PICO-60 C3 F8 Bubble Chamber. Physical Review Letters, 118(25). https://doi.org/10.1103/PhysRevLett.118.251301