Comparing multichannel cylinder and 3D-printed applicators for vaginal cuff brachytherapy with preliminary exploration of post-hysterectomy vaginal morphology

12Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To compare dosimetric parameters of multichannel cylinder (MCC) and 3-dimensional (3D)-printed plans for high-dose-rate vaginal cuff brachytherapy (VBT) and to explore vaginal morphologies after hysterectomy. Material and methods: Forty-eight patients with gynecological cancer who required VBT after hysterectomy were investigated. To develop a 3D-printed applicator, computed tomography images were obtained with contrast-soaked vaginal gauzes placed in situ to mould vaginal anatomy. 3D digital model of vaginal gauze was then generated and subsequently converted into a prototype 3D-printed applicator, and optimized source catheters were placed in the applicator. Post-hysterectomy vaginal configurations were classified via morphometric analysis of 3D-printed applicators. Results: In terms of clinical target volume (CTV) coverage, V100 was slightly larger in 3D-printed plans than in MCC plans (90.02% vs. 90.01%, p < 0.001), and D98 in 3D-printed group (429.11 cGy) was higher than that in MCC group (400.08 cGy, p < 0.001). Quality indices were superior in 3D-printed plans than in MCC plans. When evaluating proximal 1 cm of CTV from the vaginal apex (CTV-1 cm), difference in V100 was significant and favored 3D-printed plans (81.85% vs. 72.47%, p < 0.001). 3D-printed applicators demonstrated superiority over MCC in terms of bladder and rectum protection. However, it would cause higher undesired doses to sigmoid. Post-hysterectomy vaginal configurations were classified into five different types, including dome-column, Gothic arch-column, two dog ears-column, one dog ear-column, and 'up wide and low narrow'. Conclusions: Compared with MCC, 3D-printed applicators delivered a higher dose and larger volume, and offered more homogeneous and conformal target coverage. Further research on vaginal morphology will be valuable to help screen out patients who need 3D-printed applicators, and to provide guidance for designing new applicators.

Cite

CITATION STYLE

APA

Yan, J., Qin, X., Zhang, F., Hou, X., Yu, L., & Qiu, J. (2021). Comparing multichannel cylinder and 3D-printed applicators for vaginal cuff brachytherapy with preliminary exploration of post-hysterectomy vaginal morphology. Journal of Contemporary Brachytherapy, 13(6), 641–648. https://doi.org/10.5114/jcb.2021.112115

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free