Insights into the potential of rheological measurements in development of dry powder inhalation formulations

10Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Study of flow is a key to development of dry powder inhalation formulations. Various static (bulk) and dynamic rheological measurements are used to study different aspects of powder flow and packing. Among rheological measurements, the permeability and the fluidization energy are, conceptually, most relevant to dispersion of dry powder inhalation formulations. The aim of the current study was to test the robustness and the range of applications of the two measurements, among other rheological measurements. To this end, we prepared and studied a series of ternary, carrier-based dry powder inhalation formulations. The formulations were mixtures of coarse-fine excipient (α-lactose monohydrate) blends, with different fine excipient concentrations (0.0–15.0 % w/w), and a spray-dried drug (fluticasone propionate) material. The excipient blends were characterized in terms of morphology, size, crystallinity, and rheological properties. The formulations were evaluated in vitro using a low resistance inhalation device, the Cyclohaler®, and a high resistance inhalation device, the Handihaler®. The study design aimed to complement literature data. Bulk rheological measurements, specifically the bulk density, the compressibility, and the permeability, exhibited satisfactory precision and could demonstrate changes in powder composition and structure. They hold a potential for use as critical material attributes to aid monitoring and optimization of carrier-based dry powder inhalation formulations in quality-by-design systems. On the other hand, dynamic rheological measurements, specifically the basic flowability energy, the specific energy, and the fluidization energy, generally exhibited high variability, which obscured interpretation of the measurements and implied heterogeneous powder structures. The fluidization energy could, nevertheless, convey structural changes taking place during powder fluidization.

Cite

CITATION STYLE

APA

Almansour, K., Alfagih, I. M., Shalash, A. O., Brockbank, K., Ali, R., Freeman, T., & Elsayed, M. M. A. (2022). Insights into the potential of rheological measurements in development of dry powder inhalation formulations. International Journal of Pharmaceutics, 614. https://doi.org/10.1016/j.ijpharm.2021.121407

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free