Effect of Contact Angle on Steam Dropwise Condensation: A Simulation Approach

  • Nahavandi M
  • Mehrabani-Zeinabad A
N/ACitations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Dropwise condensation process on surface of a vertical polytetrafluouroethylene (PTFE) plate at atmospheric pressure was simulated. Comparison of simulated data with experimental and theoretical results indicates that performed simulation results confirm experimental data, although they deviated from existing proposed correlations. For calculation of heat transfer coefficient and droplets size distribution, simulation of condensation process over vertical copper and PTFE surfaces at atmospheric pressure was performed. By considering the effect of contact angle on heat transfer resistances of droplets, the gained data were optimized in order to evaluate droplets size distribution coefficient. This distribution coefficient was used in a new correlation for prediction of heat transfer coefficient for dropwise condensation process. Comparison of experimental results with the correlation shows a good agreement, 11% relative error.

Cite

CITATION STYLE

APA

Nahavandi, M., & Mehrabani-Zeinabad, A. (2012). Effect of Contact Angle on Steam Dropwise Condensation: A Simulation Approach. ISRN Chemical Engineering, 2012, 1–7. https://doi.org/10.5402/2012/789489