Comparison of two methods of fixation with interference screw for cranial cruciate ligament reconstruction in canine cadaver model

  • Rafael P
  • Goin B
  • Buttin P
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction With a prevalence of 4.87% in dogs, cranial cruciate ligament (LCC) rupture is the most common orthopedic involvement of the pelvic limbs (Witsberger et al. 2008). Repair techniques for these ruptures, using a synthetic intra-articular ligament, have limitations that are intrinsically linked to the materials used, which can influence the functionality of the in-situ system over time (Denny and Goodship 1980). A renewed interest has been initiated by the discovery of new medical grade fibers with interesting mechanical and biocompatible properties (such as UHMWPE fibers), that can be braided and used as a ligament reconstruction implant during rupture of the anterior cruciate ligament (ACL) in humans (Purchase et al. 2007). A gold standard for years, the interference screw is the preferred means of attachment associated with the use of these implants during ACL rupture. Numerous biomechanical studies carried out on human anatomical pieces have compared various axes and tunnel diameters in order to optimize these fixings (Aoki et al. 2019). The objective of this ex-vivo study will be to compare the biomechanical properties of two interference screw implantation techniques chosen as the fixation system for a synthetic UHMWPE implant used in the surgical treatment of LCC rupture in dogs. 2. Methods 2.1. Sample preparation protocol Fourteen hindlimbs from 7 adult dogs 29 kg +/- 2 kg (mean +/- sd) were selected. Dogs were of similar size, without any stifle lesion observed and died from reasons unrelated to the focus of this study. Stifles were dissected to leave the tibia and femur intact. Each bone extremity was fixed with resin onto two supports. 2.2. Implantation of the UHMWPE ligament Stifles were implanted with a UHMWPE ligament (Novalig, Novetech Surgery, Monaco). An oblique tibial tunnel was drilled from the craniomedial insertion of CCL. A femoral tunnel was drilled from the caudo-lateral femoral insertion. The ligament was passed through both tunnels (Figure 1). 2.3. Biomechanical testing Static tensile tests of these two techniques were performed on the stifles using a traction system (AGS- X Shimadzu, Japan) with a pre-test of 20mm/min traction until the load reached 10N, thus straightening the system. The first static test consisted in a 1-mm/min traction until failure. Failure occurs if the displacement exceeds 15mm. For the series of tests, the sampling rate for data acquisition was set at 10Hz. A total of 14 experimental set-ups were randomly considered: 7 under the first surgical implantation technique and 7 under the second. 2.4. Data acquisition and processing During tests, acquisitions of the data were carried out using the TrapeziumX software (Shimadzu, Japan). For each implantation technique, two measures were taken i. The strength recorded at 3mm (S3mm) of displacement of the cross traverse. ii. The maximum strength (Ms) and the displacement of the associated traverse stroke. iii. The mode of failure. The data were then processed with Microsoft Excel. Statistical analyses were performed using nonparametric Mann-Whitney tests. No rupture of the set-up occurred. All the mechanical tests carried out reported a localized sliding exclusively in the tibial part. A measurement of the tensile strength was recorded at 3mm displacement (S3mm). This displacement limit is equivalent to the acceptable limit of cranio-caudal amplitude of the movement of the tibia drawer, with respect to the post-operative controlled femur of an LCC reconstruction surgical technique (Loutzenheiser et al. 1995). The significant difference (S3mm) observed between the two implantation methods could be due to differences in bone density, depending on the implantation site of the interference screws. According to the theory of bone remodeling described by Wolff (1892), the interference screws implanted according to the 'In-Out' technique are placed in the LCC insertion zone, which is thicker with denser sub-chondral bone in due to the much greater mechanical stresses borne by the articular surfaces. The essentially monocortical fixation of the interference screw implanted according to the 'In- Out' technique is therefore carried out in the cortical and subchondral parts. These specific bone areas have better mechanical properties than the metaphyseal part, which is less exposed to mechanical stresses and seems to offer lower mechanical resistance when implanting the interference screws using the 'Out-In' technique. In addition, the implantation of the interference screw according to the 'In-Out' technique will act as wedge, owing to its conical shape, and limit the slip of the synthetic ligament more effectively while reducing the free part of the ligament in the intra-articular space. However, we know that the closer the fixation system is to the joint, the more solid the mounting (Scheffler et al. 2002; Bryan et al. 1996). Finally, a tensioning zone has been identified at the start of each of our mechanical tests. This displacement of the traverse stroke without linear increase in strength may be due to the tensioning of the fibers of the implant and a pre-tension of 10N may not be sufficient and physiologically representative of the in-situ efforts of the implanted prosthesis when the dog is in a static position. 4. Conclusions This study shows that in a synthetic ligamentoplasty assembly locked with two interference screws, those implanted 'In-Out' allow better initial mechanical resistance (<3mm) of the LCC ligament reconstruction system than those implanted 'Out- In'. The rupture mode is similar for the two implantation techniques, as a slip of the synthetic implant is observed between the walls of the tibial tunnel and the interference screw.

Cite

CITATION STYLE

APA

Rafael, P., Goin, B., Buttin, P., Cachon, T., & Viguier, E. (2020). Comparison of two methods of fixation with interference screw for cranial cruciate ligament reconstruction in canine cadaver model. Computer Methods in Biomechanics and Biomedical Engineering, 23(sup1), S247–S249. https://doi.org/10.1080/10255842.2020.1812846

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free