Optimal design of mass timber panels as dynamic insulation: Simulations of steady and transient heat exchange

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Mass timber panels could be designed as heat exchangers for use in building envelopes. Fresh air, drawn through geometrically optimized channels in the panel, is pre-tempered with building heat that would otherwise be lost to the exterior via conduction. Recent experiments have shown that timber heat exchanging panels can approach U ~0.1 W/m2K - but there are potential limitations. The sizing correlations which predict panel geometry and steady heat exchange must be numerically calibrated for building-scale contexts, the heat-exchange efficiency must be verified virtually, and practical thresholds for transient response time must be determined. This study uses numerical simulations to investigate these factors for one design 'case' of timber panels, and establishes a methodology for studies of further cases.

Cite

CITATION STYLE

APA

Halepaska, A., & Craig, S. (2021). Optimal design of mass timber panels as dynamic insulation: Simulations of steady and transient heat exchange. In Journal of Physics: Conference Series (Vol. 2042). IOP Publishing Ltd. https://doi.org/10.1088/1742-6596/2042/1/012185