Respiration-based sorting of dynamic MRI to derive representative 4D-MRI for radiotherapy planning

99Citations
Citations of this article
100Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited "snap-shot" in time. To potentially address this, the authors have developed a longer-duration MRI and postprocessing technique to derive the average or most-probable state of mobile anatomy and meanwhile capture and convey the observed motion variability. Methods: Sagittal and coronal multislice, 2D dynamic MRI was acquired in a sequential fashion over extended durations in two abdominal and four lung studies involving healthy volunteers. Two sequences, readily available on a commercial system, were employed. Respiratory interval-correlated, or 4D-MRI, volumes were retrospectively derived using a two-pass approach. In a first pass, a respiratory trace acquired simultaneous with imaging was processed and slice stacking was used to derive a set of MRI volumes, each representing an equal time or proportion of respiration. Herein, all raw 2D frames mapping to the given respiratory interval, per slice location, were averaged. In a second-pass, this prior reconstruction provided a set of template images and a similarity metric was employed to discern the subset of best-matching raw 2D frames for secondary averaging (per slice location and respiratory interval). Breathing variability (per respiratory interval and slice location) was depicted by computing both a maximum intensity projection as well as a pixelwise standard deviation image. Results: These methods were successfully demonstrated in both the lung and abdomen for both applicable sequences, performing reconstructions with ten respiratory intervals. The first-pass (average) resulted in motion-induced blurring, especially for irregular breathing. The authors have demonstrated qualitatively that the second-pass result can mitigate this blurring. Conclusions: They have presented a novel methodology employing dMRI to derive representative 4D-MRI. This set of techniques are practical in that (1) they employ MRI sequences that are standard across commercial vendors; (2) the 2D imaging planes can be oriented onto an arbitrary axis (e.g., sagittal, coronal, axial⋯); (3) the image processing techniques are relatively simple. Systematically applying this and similar dMRI-based techniques in patients is a crucial next step to demonstrate efficacy beyond CT-only based practice. © 2013 American Association of Physicists in Medicine.

Author supplied keywords

Cite

CITATION STYLE

APA

Tryggestad, E., Flammang, A., Han-Oh, S., Hales, R., Herman, J., McNutt, T., … Wong, J. (2013). Respiration-based sorting of dynamic MRI to derive representative 4D-MRI for radiotherapy planning. Medical Physics, 40(5). https://doi.org/10.1118/1.4800808

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free