Abstract
Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited "snap-shot" in time. To potentially address this, the authors have developed a longer-duration MRI and postprocessing technique to derive the average or most-probable state of mobile anatomy and meanwhile capture and convey the observed motion variability. Methods: Sagittal and coronal multislice, 2D dynamic MRI was acquired in a sequential fashion over extended durations in two abdominal and four lung studies involving healthy volunteers. Two sequences, readily available on a commercial system, were employed. Respiratory interval-correlated, or 4D-MRI, volumes were retrospectively derived using a two-pass approach. In a first pass, a respiratory trace acquired simultaneous with imaging was processed and slice stacking was used to derive a set of MRI volumes, each representing an equal time or proportion of respiration. Herein, all raw 2D frames mapping to the given respiratory interval, per slice location, were averaged. In a second-pass, this prior reconstruction provided a set of template images and a similarity metric was employed to discern the subset of best-matching raw 2D frames for secondary averaging (per slice location and respiratory interval). Breathing variability (per respiratory interval and slice location) was depicted by computing both a maximum intensity projection as well as a pixelwise standard deviation image. Results: These methods were successfully demonstrated in both the lung and abdomen for both applicable sequences, performing reconstructions with ten respiratory intervals. The first-pass (average) resulted in motion-induced blurring, especially for irregular breathing. The authors have demonstrated qualitatively that the second-pass result can mitigate this blurring. Conclusions: They have presented a novel methodology employing dMRI to derive representative 4D-MRI. This set of techniques are practical in that (1) they employ MRI sequences that are standard across commercial vendors; (2) the 2D imaging planes can be oriented onto an arbitrary axis (e.g., sagittal, coronal, axial⋯); (3) the image processing techniques are relatively simple. Systematically applying this and similar dMRI-based techniques in patients is a crucial next step to demonstrate efficacy beyond CT-only based practice. © 2013 American Association of Physicists in Medicine.
Author supplied keywords
Cite
CITATION STYLE
Tryggestad, E., Flammang, A., Han-Oh, S., Hales, R., Herman, J., McNutt, T., … Wong, J. (2013). Respiration-based sorting of dynamic MRI to derive representative 4D-MRI for radiotherapy planning. Medical Physics, 40(5). https://doi.org/10.1118/1.4800808
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.