Abstract
An algorithm to detect inter-turn faults in induction motors based on the negative sequence impedance is presented in this paper. The implementation through a digital prototype is also explained and its results are tested using a 3 Hp induction motor designed to induce inter-turn faults. It is concluded that the robustness of the algorithm can detect incipient faults from five turns, and it is a good tool for predictive maintenance of induction motors.
Cite
CITATION STYLE
Villada, F., Cadavid, D. R., Aedo, J. E., Benavides, B. A., & Velilla, E. (2013). The negative sequence impedance as fault indicator in induction motors. Revista Facultad de Ingeniería Universidad de Antioquia, (51), 7–13. https://doi.org/10.17533/udea.redin.14819