An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: The mini-fluid challenge study

272Citations
Citations of this article
303Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Predicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness. Methods: Thirty-nine critically ill ventilated and sedated patients with acute circulatory failure were prospectively studied. Subaortic VTI was measured by transthoracic echocardiography before fluid infusion (baseline), after 100 ml hydroxyethyl starch infusion over 1 min, and after an additional infusion of 400 ml hydroxyethyl starch over 14 min. The authors measured the variation of VTI after 100 ml fluid (ΔVTI100) for each patient. Receiver operating characteristic curves were generated for (ΔVTI100). When available, receiver operating characteristic curves also were generated for pulse pressure variation and central venous pressure. Results: After 500 ml volume expansion, VTI increased 15% in 21 patients (54%) defined as responders. ΔVTI100 10% predicted fluid responsiveness with a sensitivity and specificity of 95% and 78%, respectively. The area under the receiver operating characteristic curves of ΔVTI100 was 0.92 (95% CI: 0.78-0.98). In 29 patients, pulse pressure variation and central venous pressure also were available. In this subgroup of patients, the area under the receiver operating characteristic curves for ΔVTI100, pulse pressure variation, and central venous pressure were 0.90 (95% CI: 0.74-0.98, P < 0.05), 0.55 (95% CI: 0.35-0.73, NS), and 0.61 (95% CI: 0.41-0.79, NS), respectively. Conclusion: In patients with low volume mechanical ventilation and acute circulatory failure, ΔVTI100 accurately predicts fluid responsiveness. © 2011, the American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins.

Cite

CITATION STYLE

APA

Muller, L., Toumi, M., Bousquet, P. J., Riu-Poulenc, B., Louart, G., Candela, D., … Lefrant, J. Y. (2011). An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: The mini-fluid challenge study. Anesthesiology, 115(3), 541–547. https://doi.org/10.1097/ALN.0b013e318229a500

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free