Evaluation of a single-breath-hold radial turbo-spin-echo sequence for T2 mapping of the liver at 3T

11Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: T2 mapping of the liver is a potential diagnostic tool, but conventional techniques are difficult to perform in clinical practice due to long scan time. We aimed to evaluate the accuracy of a prototype radial turbo-spin-echo (rTSE) sequence, optimized for multi-slice T2 mapping in the abdomen during one breath-hold at 3 T. Methods: A multi-sample (fat: 0–35%) agarose phantom doped with MnCl2 and 80 subjects (73 patients undergoing abdomen MR examination and 7 healthy volunteers) were investigated. A radial turbo-spin-echo (rTSE) sequence with and without fat suppression, a Cartesian turbo-spin-echo (Cart-TSE) sequence, and a single-voxel multi-echo STEAM spectroscopy (HISTO) were performed in phantom, and fat-suppressed rTSE and HISTO sequences were performed in in vivo measurements. Two approaches were used to sample T2 values: manually selected circular ROIs and whole liver analysis with Gaussian mixture models (GMM). Results: The rTSE-T2s values exhibited a strong correlation with Cart-TSE-T2s (R2 = 0.988) and with HISTO-T2s of water (R2 = 0.972) in phantom with an offset between rTSE and Cart-TSE maps (mean difference = 3.17 ± 1.18 ms). The application of fat suppression decreased T2 values, and the effect was directly proportional to the amount of fat. Measurements in patients yielded a linear relationship between rTSE- and HISTO-T2s (R2 = 0.546 and R2 = 0.580 for ROI and GMM, respectively). Conclusion: The fat-suppressed rTSE sequence allows for fast and accurate determination of T2 values of the liver, and appears to be suitable for further large cohort studies. Key Points: •Radial turbo-spin-echo T2 mapping performs comparably to Cartesian TSE-T2 mapping, but an offset in values is observed in phantom measurements. •Fat-suppressed radial turbo-spin-echo T2 mapping is consistent with T2 of water as assessed by MRS in phantom measurements. •Fat-suppressed radial turbo-spin-echo sequence allows fast T2 mapping of the liver in a single breath-hold and is correlated with MRS-based T2 of water.

Cite

CITATION STYLE

APA

Bencikova, D., Han, F., Kannengieser, S., Raudner, M., Poetter-Lang, S., Bastati, N., … Krššák, M. (2022). Evaluation of a single-breath-hold radial turbo-spin-echo sequence for T2 mapping of the liver at 3T. European Radiology, 32(5), 3388–3397. https://doi.org/10.1007/s00330-021-08439-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free