The Sapien valve provides enough grip to be implanted in pulmonary position without a pre-stent

8Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Background: Pre-stenting is a widely used technique for transcatheter pulmonary valve implantation (TPVI). For the Melody valve a pre-stent creates a reliable and solid landing zone. In contrast to the Melody valve, the Edwards Sapien valve consists of a strong balloon expandable stent designed for implantation in the aortic position. The usage of a Sapien valve in pulmonary position might therefore obviate the need of a pre-stent. Methods: This retrospective, single centre study reviewed the procedural outcomes of patients receiving the Sapien XT transcatheter valve in pulmonary position without prior implantation of a pre-stent. All consecutive patients with dysfunctional right ventricle to pulmonary artery (RV-PA) conduits or with dysfunctional pulmonary valve treated at the German Heart Centre in Munich were included in this study. Results: We report on successful implantation of a Sapien XT/3 without usage of a pre-stent. Conclusions: Abandonment of the pre-stent simplified the procedure and reduces the radiation burden for the patients.

Cite

CITATION STYLE

APA

Tanase, D., Georgiev, S., Eicken, A., & Ewert, P. (2019). The Sapien valve provides enough grip to be implanted in pulmonary position without a pre-stent. Cardiovascular Diagnosis and Therapy, 9, S264–S268. https://doi.org/10.21037/CDT.2019.09.08