The effects of absorbed moisture on thermal protective performance of fire-fighters' clothing materials under radiant heat flux conditions were analyzed in this paper. A thermal protective performance tester and temperature sensor were used to measure the temperature variations for the facecloth side of four kinds of commonly used flame retardant fabrics in several radiant heat exposures, which varied in moisture content. Experimental results showed that, all of the temperature profiles of these four kinds of moistened fabrics under different radiant heat flux conditions presented the same variation trend. The addition of moisture had a positive influence on the thermal protective performance during the constant temperature period when heat radiation time was more than 60 seconds. As the heat radiation time increased beyond 500 seconds, the thermal protective performance of moistened fabrics became worse than that of dried fabrics in general.
Author supplied keywords
Cite
CITATION STYLE
Chen, M., Zhu, F., Feng, Q., Li, K., & Liu, R. (2017). Experimental study on moisture transfer through firefighters’ protective fabrics in radiant heat exposures. Thermal Science, 21(4), 1665–1671. https://doi.org/10.2298/TSCI160512051C