The efficacy of post-tensioned metal straps PTMS, wrapped around steel channels anchored to normal reinforced concrete (R.C) beams is tested in increasing the flexural capacity of the beams. For this purpose, nine normal R.C beams with dimensions of 160 mm x 240 mm x 2100 mm are constructed to fail in bending. The location and the number of the straps are considered as the main variable. It is found that using PTMS can enhance the load-carrying capacity of the beam by 29% to 63%. The decisive factors affecting the increase are the location of the straps (at the bottom or sides), shape of the flange and web edges (squared or rounded) and alignment of the flanges (vertical or inclined). A complete guide can be found in the paper as it is a novel method of strengthening beams which can be applied to the beams cast in place with integral slabs.