First-in-Human Side-to-Side Magnetic Compression Duodeno-ileostomy with the Magnet Anastomosis System

33Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purposes: Classical gastrointestinal anastomoses are formed with sutures and/or metal staples, resulting in significant bleeding and leak rates. This study evaluated the feasibility and safety of the novel magnet anastomosis system (MS) to create a side-to-side duodeno-ileal (DI) diversion for weight loss and type 2 diabetes (T2D) resolution. Materials and Methods: Patients with severe obesity (body mass index (BMI) ≥ 35 kg/m2 with/without T2D (HbA1C ≥ 6.5%)) underwent the study procedure, a side-to-side MS DI diversion, with a standard sleeve gastrectomy (SG). A linear magnet was delivered by flexible endoscopy to a point 250 cm proximal to the ileocecal valve; a second magnet was positioned in the first part of the duodenum; the bowel segments containing magnets were apposed, initiating gradual anastomosis formation. Laparoscopic assistance was used to obtain bowel measurements, obviate tissue interposition, and close mesenteric defects. Results: Between November 22 and 26, 2021, 5 female patients (mean weight 117.6 ± 7.1 kg, BMI (kg/m2) 44.4 ± 2.2) underwent side-to-side MS DI + SG. All magnets were successfully placed, expelled without re-intervention, and formed patent durable anastomoses. Total weight loss at 12 months was 34.0 ± 1.4% (SEM); excess weight loss, 80.2 ± 6.6%; and BMI reduction, 15.1. Mean HbA1C (%) dropped from 6.8 ± 0.8 to 4.8 ± 0.2; and glucose (mg/dL), from 134.3 ± 17.9 to 87.3 ± 6.3 (mean reduction, 47.0 mg/dL). There was no anastomotic bleeding, leakage, obstruction, or infection and no mortality. Conclusions: Creation of a side-to-side magnetic compression anastomosis to achieve duodeno-ileostomy diversion in adults with severe obesity was feasible and safe, achieved excellent weight loss, and resolved type 2 diabetes at 1-year follow-up. Trial Registration: Clinicaltrials.gov Identifier: NCT05322122. Graphical Abstract: [Figure not available: see fulltext.]

Cite

CITATION STYLE

APA

Gagner, M., Abuladze, D., Koiava, L., Buchwald, J. N., Van Sante, N., & Krinke, T. (2023). First-in-Human Side-to-Side Magnetic Compression Duodeno-ileostomy with the Magnet Anastomosis System. Obesity Surgery, 33(8), 2282–2292. https://doi.org/10.1007/s11695-023-06708-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free