Abstract
A full scale Reinforced concrete (RC) frame assemblage was constructed and induced a predefined level of damage by subjecting the frame to simulated seismic loads and then was tested against a designed 1 h compartment fire. The RC frame was instrumented with a number of sensors which recorded strains, displacements and temperatures during the test. This paper provides a report on a full scale RC frame subjected to post earthquake fire. The frame could withstand the fire without collapse however the residual capacity of the frame was reduced to 65 % of the original. Important observations have been made about the development of the temperatures and displacements in various elements during the test.
Author supplied keywords
Cite
CITATION STYLE
Shah, A. H., Sharma, U. K., Bhargava, P., Reddy, G. R., Singh, T., & Lakhani, H. (2015). A full scale fire test on a pre damaged RC framed structure. In Advances in Structural Engineering: Materials, Volume Three (pp. 2259–2274). Springer India. https://doi.org/10.1007/978-81-322-2187-6_171
Register to see more suggestions