Transcutaneously measured near-infrared spectroscopic liver tissue oxygenation does not correlate with hepatic venous oxygenation in children

21Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare transcutaneous near-infrared spectroscopic (NIRS) measured liver tissue oxygenation with hepatic vein oxygen saturation (SvhO2) in children undergoing cardiac catheterization. Methods: A NIRS optode (containing an emitter and a receiver of near-infrared light) was placed directly below the right costal arch above the palpable liver in 40 children aged 0.02 to 7.28 yr (median: 1.8 yr). Spatially resolved spectroscopic measured tissue oxygenation index (TOI) was recorded using the NIRO-300™. Paired blood samples from the hepatic vein were taken under radiological control for determination of SvhO2 in a co-oxymeter. TOI values were compared with hepatic vein oxygenation, with simultaneously obtained arterial oxygen saturation (SaO2), inferior vena java SO2 and hemoglobin concentration using simple linear and multi-regression analysis. Results: TOI values ranged from 35% to 73% (58.6 ± 8.4%); SvhO2 from 32% to 80% (58.4 ± 14.4%), and arterial SO2 from 54% to 100% (90.0 ± 11.4%). TOI and hepatic vein oxygen saturation failed to correlate (r = 0.052/P = 0.752). A regression model containing arterial saturation (ΔR2 = 0. 177) and the ratio of pulmonary to systemic resistance (ΔR2 = 0.095) explained 27.3% of the observed variance in TOI. In this model, hepatic vein oxygen saturation was no longer significant; explaining only 3.4% of the variance. No other variable retained a significant association. Conclusion: Transcutaneously measured NIRS tissue oxygenation with an optode placed over the palpable liver does not correlate with SvhO2. The value is dominated by non-hepatic variables such as arterial saturation and vascular resistances.

Cite

CITATION STYLE

APA

Weiss, M., Schulz, G., Fasnacht, M., Balmer, C., Fischer, J. E., Gerber, A. C., … Baenziger, O. (2002). Transcutaneously measured near-infrared spectroscopic liver tissue oxygenation does not correlate with hepatic venous oxygenation in children. Canadian Journal of Anesthesia, 49(8), 824–829. https://doi.org/10.1007/BF03017416

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free