Abstract
Single-cell analysis is of increasing importance in many fields, but is challenging due to the ultra-small volumes (picoliters) of single cells. Indeed, analysis of a specific analyte might require the analysis of a single molecule or several molecules. Analytical processes usually include sampling, chemical processing, and detection. Although several papers have reported chemical processing and detection methods for single cells, a sampling method compatible with maintaining the viability of a single cell during sampling has yet to be developed. Here, we propose a femtoliter sampling method from a living single cell using micro/nanofluidic device technology. The sampling of 39 fL of cytoplasm from a single human aortic endothelial cell was demonstrated and its viability after sampling was confirmed.
Cite
CITATION STYLE
Lin, L., Mawatari, K., Morikawa, K., Pihosh, Y., Yoshizaki, A., & Kitamori, T. (2017). Micro/extended-nano sampling interface from a living single cell. Analyst, 142(10), 1689–1696. https://doi.org/10.1039/c7an00220c